Hybrid Inverter
ET G2 Series
GoodWe GW9900-ET-20 9.99kW Three-Phase Hybrid Inverter
The GoodWe GW9900-ET-20 is a 9.99kW three-phase hybrid inverter in GoodWe's ET G2 Series. Designed for solar generation and compatible high-voltage battery integration, it features three independent MPPT trackers, up to 16kW maximum PV input power and configurable backup functionality. Battery selection, backup performance and grid connection requirements depend on the complete system design and applicable manufacturer and network conditions.

Key information
- Product Code
- GW9900-ET-20
- Brand
- GoodWe
- Series
- ET G2 Series
- Type
- Three-Phase Hybrid Inverter
- Nominal AC Output
- 9.990kW
- Maximum PV Input
- 16.0kW
- MPPT Trackers
- 3
- Battery Voltage Range
- 150–720V
- Maximum Efficiency
- 98.2%
- Warranty
- 10 years (AU/NZ inverter system warranty for ET G2)
Product overview
Australian ET G2 Three-Phase Hybrid Inverter
This page documents the Australian-market GoodWe GW9900-ET-20. Exact nominal AC output is 9,990W (9.990kW). It is not the international GW10K-ET-20, not an ESA Series single-phase EHA power module, and not a battery or complete storage system by itself.
Technical values follow the Australian GoodWe ET G2 datasheet column for GW9900-ET-20 (GoodWe-Single page-20250808-AU-V2.1). Battery storage and backup operation require compatible batteries, correct wiring and a complete system configuration.
Product features
9.99kW Three-Phase Hybrid Inverter
GoodWe rates the Australian GW9900-ET-20 at 9,990W nominal AC output power, with 9,990VA nominal and maximum apparent power to the utility grid. Approximate “9.9kW” wording may be used descriptively, but the exact manufacturer rating is 9.990kW / 9,990VA.
This three-phase ET G2 model must not be confused with GoodWe ESA Series single-phase hybrid power modules such as GW9.999K-EHA-G20 or GW6K-EHA-G20.
GoodWe ET G2 Architecture
ET G2 is GoodWe’s three-phase high-voltage hybrid inverter platform for residential and light commercial systems. The inverter manages PV generation, grid interaction and compatible battery storage. Buying the inverter alone does not include battery capacity.
Manufacturer material states parallel connection of up to four ET G2 units is supported for higher capacity designs, subject to firmware alignment, metering, wiring and commissioning requirements. Not every site can or should operate four inverters in parallel.
Three Independent MPPT Trackers
The GW9900-ET-20 has three MPPT trackers with one string per MPPT. Maximum input current per MPPT is 16A and maximum short-circuit current per MPPT is 24A.
Three trackers support multi-orientation roofs within the voltage and current windows. Lower ET G2 models such as GW6000-ET-20 and GW8000-ET-20 use two MPPTs; do not assume every ET G2 model has three trackers.
Up to 16kW PV Input
GoodWe lists maximum PV input power of 16,000W for GW9900-ET-20, with maximum PV input voltage of 1,000V, MPPT operating range 120–850V, PV start-up voltage 150V and nominal PV input voltage 620V.
Maximum PV input power is not AC output power. Footnotes state maximum input power is not continuous at 1.6× normal power. For 1,000V systems, maximum operating voltage is 950V; between 975V and 1,000V the inverter enters standby until voltage returns to 975V.
High-Voltage Battery Integration
On the battery side, GoodWe lists Li-Ion chemistry (LFP and ternary lithium as mainstream types), nominal battery voltage 500V, battery voltage range 150–720V, start-up voltage 150V and one battery input.
Those figures describe the inverter battery port, not a blanket guarantee for every GoodWe battery. Current GoodWe compatibility documentation lists ET G2 models including GW9900-ET-20 with Lynx Home F G2 and Lynx D / Lynx D G2 families, subject to firmware, module counts and commissioning requirements. Confirm the exact battery model before specifying a system.
Battery Charging and Discharging
For GW9900-ET-20, GoodWe lists maximum continuous charging and discharging current of 40A, maximum charging power of 15,000W and maximum discharging power of 11,000W.
Battery DC power is not the same as the inverter’s 9.990kW AC nominal output. Actual battery power depends on the connected battery, state of charge, temperature and system settings.
Three-Phase Energy Management
The inverter connects as three-phase 400/380V, 3L/N/PE, with nominal grid frequency 50/60Hz. Maximum apparent power from the utility grid is 20,000VA. Maximum AC current to the grid is 14.5A; maximum AC current from the grid is 26.1A, subject to the datasheet breaker footnote.
Peak shaving and smart load control are manufacturer-described ET G2 functions. Real outcomes depend on meter arrangement, firmware, battery availability and DNSP rules.
Unbalanced Load Support
GoodWe ET G2 marketing describes 100% unbalanced three-phase output as a series capability. That does not mean unlimited power is available on a single phase, and the current AU ET G2 datasheet technical table (20250808-AU-V2.1) does not publish a separate per-phase unbalanced rating for GW9900-ET-20.
Per-phase limits, backup unbalance behaviour and load management still depend on firmware, wiring, meters, battery capability and installation design. Decarby treats unbalanced-output claims as conditional system features, not as an unconditional single-phase power rating.
Backup Power and EPS
The AU datasheet lists backup nominal apparent power of 10,000VA for GW9900-ET-20. Maximum output apparent power without grid is 10,000VA with 18,000VA for 60 seconds, reachable only if PV and battery power are sufficient. Maximum output apparent power with grid is 10,000VA. Maximum backup output current is 21.7A (26.1A for 60 seconds).
Manufacturer marketing states UPS-level switching under 10ms. Backup still requires a compatible battery, correct backup wiring, protection equipment and installation design. It does not guarantee every household or commercial load will run during an outage.
Monitoring and Smart Controls
The AU datasheet lists LED user interface with WLAN and APP, RS485 and CAN communication with the BMS, RS485 with the meter, and Wi-Fi plus LAN and Bluetooth for portal communication. Integrated dry contact for external loads is listed in the series feature set.
Monitoring is commonly delivered through GoodWe SEMS / app tooling. Exact dongle, meter and portal package depends on the hardware kit supplied with the installation.
Conversion Efficiency
For GW9900-ET-20, the AU datasheet lists maximum efficiency of 98.2%, European efficiency of 97.5%, maximum battery-to-AC efficiency of 97.5% and MPPT efficiency of 99.5%.
These four figures are different metrics and must not be interchanged. 97.5% appears as both European and battery-to-AC efficiency on this model; maximum inverter efficiency remains 98.2%.
Electrical Safety and Protection
Manufacturer-listed protections include PV insulation resistance detection, residual current monitoring, PV and battery reverse-polarity protection, anti-islanding, AC overcurrent, short-circuit and overvoltage protection, integrated DC switch, Type II DC and AC surge protection, and remote shutdown. PV AFCI 3.0 is optional.
Protection features support a safer installation only when the complete system is designed and commissioned to Australian Standards and manufacturer instructions. Confirm current CEC and grid certificates for the exact hardware revision supplied.
Installation and Environmental Conditions
GoodWe specifies an IP66 ingress-protection rating, natural-convection cooling, wall mounting, dimensions 496 × 460 × 221mm and weight 25kg for GW9900-ET-20. Operating environment is listed as outdoor.
Operating temperature is -35°C to +60°C. Relative humidity is 0–100%. Maximum altitude is 4000m. Do not use ESA Series mechanical figures for this ET G2 inverter.
Australian Warranty and Support
The GOODWE Limited Warranty for Inverter System (Australia and New Zealand) includes ET G2 series hybrid inverters under the 10-year limited product warranty category, subject to authorised supply, qualified installation and the warranty exclusions.
That inverter warranty is separate from any battery performance, energy-retention or throughput warranty that may apply to a connected battery product. Do not treat battery warranty terms as inverter performance guarantees.
Technical details
GoodWe GW9900-ET-20 Specifications
General
| Model | GW9900-ET-20 |
|---|---|
| Series | ET G2 Series |
| Product type | Three-phase high-voltage hybrid inverter |
| Market note | Australian-market model (not GW10K-ET-20) |
| Topology | Non-isolated |
| Country of manufacture | China |
| Datasheet | GW_ET-G2_Datasheet-AU (GoodWe-Single page-20250808-AU-V2.1) |
PV Input
| Maximum PV input power | 16,000W |
|---|---|
| Maximum PV input voltage | 1,000V |
| Maximum operating voltage note | 950V for 1,000V systems; standby between 975–1,000V until voltage returns to 975V |
| MPPT operating voltage range | 120–850V |
| PV start-up voltage | 150V |
| Nominal PV input voltage | 620V |
| Number of MPPTs | 3 |
| Strings per MPPT | 1 / 1 / 1 |
| Maximum current per MPPT | 16A |
| Maximum short-circuit current per MPPT | 24A |
| PV oversizing note | Max. input power is not continuous at 1.6× normal power (datasheet footnote) |
Battery Input
| Compatible battery chemistry (datasheet) | Li-Ion (LFP and ternary lithium noted as mainstream types) |
|---|---|
| Nominal battery voltage | 500V |
| Battery voltage range | 150–720V |
| Battery start-up voltage | 150V |
| Number of battery inputs | 1 |
| Maximum continuous charging current | 40A |
| Maximum continuous discharging current | 40A |
| Maximum charging power | 15,000W |
| Maximum discharging power | 11,000W |
| Compatibility note | Confirm exact battery model, firmware and module limits against current GoodWe compatibility documentation for GW9900-ET-20 / ET G2 |
AC Grid Output
| Nominal AC output power | 9,990W (9.990kW) |
|---|---|
| Nominal apparent power to grid | 9,990VA |
| Maximum apparent power to grid | 9,990VA (subject to local grid regulation) |
| Maximum apparent power from grid | 20,000VA |
| Nominal grid voltage | 400 / 380V, 3L/N/PE |
| Output voltage range | 170–290V (phase voltage) |
| Nominal frequency | 50 / 60Hz |
| Frequency range | 45–65Hz |
| Maximum current to grid | 14.5A |
| Maximum current from grid | 26.1A (datasheet footnote regarding 3×25A AC breaker sizing applies) |
| Power factor | 0.8 leading to 0.8 lagging |
| THDi | <3% |
Backup / EPS
| Nominal backup apparent power | 10,000VA |
|---|---|
| Maximum apparent power without grid | 10,000VA (18,000VA for 60 seconds); only if PV and battery power are sufficient |
| Maximum apparent power with grid | 10,000VA |
| Maximum backup output current | 21.7A (26.1A for 60 seconds) |
| Backup switching | <10ms UPS-level switching (manufacturer series statement) |
| Nominal backup voltage / frequency | 400 / 380V; 50 / 60Hz |
| Output THDv (@ linear load) | <3% |
| Backup requirements | Compatible battery, backup wiring, protection equipment and complete system configuration required |
Efficiency
| Maximum efficiency | 98.2% |
|---|---|
| European efficiency | 97.5% |
| Maximum battery-to-AC efficiency | 97.5% |
| MPPT efficiency | 99.5% |
Monitoring and Communication
| User interface | LED, WLAN + APP |
|---|---|
| BMS communication | RS485, CAN |
| Meter communication | RS485 |
| Portal communication | Wi-Fi + LAN + Bluetooth |
| Series smart-control notes | Integrated dry contact for external loads; peak shaving listed in ET G2 feature set |
Protection and Compliance
| Listed protections | PV insulation resistance detection; residual current monitoring; PV/battery reverse polarity; anti-islanding; AC overcurrent/short-circuit/overvoltage; integrated DC switch; Type II DC/AC SPD; remote shutdown |
|---|---|
| PV AFCI 3.0 | Optional |
| Active anti-islanding method | AFDPF + AQDPF (datasheet) |
| Overvoltage category | DC II / AC III |
| Protective class | I |
| Environmental category | 4K4H |
| Certificates | Confirm current CEC and safety certificates on the GoodWe website for the exact hardware revision |
Mechanical and Environmental
| Dimensions (W × H × D) | 496 × 460 × 221mm |
|---|---|
| Weight | 25kg |
| Ingress protection | IP66 |
| Cooling method | Natural convection |
| Mounting method | Wall mounted |
| Operating environment | Outdoor |
| Operating temperature | -35°C to +60°C |
| Relative humidity | 0–100% |
| Maximum operating altitude | 4000m |
Warranty
| Document | GOODWE Limited Warranty for Inverter System (Australia and New Zealand) |
|---|---|
| Inverter product warranty | 10 years for ET G2 series hybrid inverters, including GW9900-ET-20 |
| Warranty start | Earlier of first installation date or 12 months after production |
| Battery performance warranty note | Battery energy-retention or throughput terms apply to battery products only, not to this inverter |
| Key conditions | Subject to authorised channel, qualified installation, claim process and exclusions in the warranty document |
Manufacturer-listed protection and compliance notes
Protections listed on AU ET G2 datasheet
- Anti-islanding protection
- Type II DC and AC surge protection
- Integrated DC switch
- IP66 ingress protection
- Optional PV AFCI 3.0
Certificates
- Confirm current CEC and safety certificates on the GoodWe website for the exact hardware revision supplied
Choosing your inverter
Is the GoodWe GW9900-ET-20 Right for Your Property?
Inverter selection should be based on the complete energy system. Three-phase supply, solar array size, household or small-commercial demand, battery plans, backup needs and DNSP rules all affect whether a 9.990kW ET G2 inverter is appropriate.
Decarby designs hybrid systems around those constraints rather than selecting an inverter from a rounded 9.9kW or 10kW label alone.
Three-phase supply
This is a three-phase hybrid inverter. It is not a substitute for ESA single-phase power modules.
Solar array
Three MPPTs and up to 16kW PV input help complex roofs, but string design still has to fit the electrical windows.
Battery plans
Storage needs a manufacturer-compatible battery; the inverter alone does not provide usable storage capacity.
Backup needs
Use the AU datasheet backup ratings, including the 18kVA / 60s peak condition, and design critical loads accordingly.
Network rules
Export limits and DNSP requirements can constrain inverter settings and system size.
Not Sure What System You Need?
You don't need to have the answer before you call us.
Tell us about your home, your electricity use and what you're hoping to achieve. We'll help you work through what makes sense whether that's solar now, solar and battery together, or a system designed so you can add more later.
Practical advice. No sales pressure.
Related products
PRODUCT FAQ
Questions About the GoodWe GW9900-ET-20
What is the GoodWe GW9900-ET-20?
It is an Australian-market three-phase hybrid inverter in GoodWe's ET G2 Series. Exact nominal AC output is 9,990W (9.990kW). It is not a battery module and not a complete storage system by itself.
Is this the same as the GW10K-ET-20?
No. GW9900-ET-20 is the Australian model with 9,990W / 9,990VA nominal and maximum AC output to the grid. International GW10K-ET-20 documentation uses 10,000W / 10,000VA ratings and must not be substituted silently.
Is this the same as GoodWe ESA hybrid inverters?
No. ESA models such as GW9.999K-EHA-G20 and GW6K-EHA-G20 are single-phase ESA power modules. GW9900-ET-20 is a three-phase ET G2 hybrid inverter with different electrical and mechanical ratings.
How many MPPTs and how much PV input does it support?
GW9900-ET-20 has three MPPTs with one string per MPPT and maximum PV input power of 16,000W. Maximum PV input is not the same as AC output power.
What is the efficiency of the GW9900-ET-20?
The AU ET G2 datasheet lists maximum efficiency 98.2%, European efficiency 97.5%, maximum battery-to-AC efficiency 97.5% and MPPT efficiency 99.5%.
Does buying this inverter include a battery?
No. The GW9900-ET-20 is the hybrid inverter. Storage requires a compatible high-voltage battery and a correctly configured complete system.
Is it compatible with the GoodWe GW8.3-BAT-D-G20 battery?
GoodWe battery compatibility documentation lists Lynx D G2 modules including GW8.3-BAT-D-G20 against the ET G2 series, with ET G2 firmware requirements noted (ARM 18 and DSP 06 or above in the compatibility overview footnote). Compatibility should still be confirmed for the exact project firmware, stack limits and commissioning requirements.
What backup power does the GW9900-ET-20 provide?
The AU datasheet lists 10,000VA nominal backup apparent power and 10,000VA maximum without grid, with 18,000VA for 60 seconds if PV and battery power are sufficient. Do not use a 20kVA backup-peak figure for this AU model column. Backup is not a guarantee that every load will run during an outage.
What warranty applies in Australia?
The GOODWE Limited Warranty for Inverter System for Australia and New Zealand includes ET G2 series hybrid inverters under a 10-year limited product warranty, subject to terms. Battery performance warranty terms, if any, apply to battery products separately.